Serial Communication Unit Features

High-speed, large-capacity communication of up to 960 words (in the case of MC protocol communication) at speeds up to 230.4 kbps is possible. Data can be read and written from/to the sequencer from external devices (PC, display, etc.) using the MC protocol. Non-procedural protocol communication is supported to permit data exchange between the sequencer and a given external device (barcode reader, measuring instrument, etc.) in any communication protocol specified by the external device. Sequencers can be programmed and monitored from a programming tool based on RS-232 serial communication using the QJ71C24N(-R2). The QJ71C24N(-R2) has a function supporting public network modems and is capable of initializing an applicable modem and connecting with the other device to communicate with any remote device or programming tool via the modem and a public network. The QJ71C24N(-R2) has a remote password function that prevents illegal access to the Q-series sequencers using the QJ71C24N(-R2)'s modem function.

QJ71C24N Specifications

InterfaceCH. 1RS-232 compliant (D-Sub 9P)CH. 2RS-422/485-compliant (2-piece terminal block)Communication MethodCircuitFull-duplex Communication / Half-duplex CommunicationMELSEC Communication Protocol CommunicationHalf-duplex communicationCommunication Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationNonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationBidirectional Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationSynchronization MethodAsynchronous methodTransmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps · 230,400 bps is available only on CH1 side (not available on CH2 side) · The total transmission speed of the two interfaces must be within 230,400 bps · When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bpsData FormatStart Bit1Data Bit7/8Parity Bit1 (Vertical parity) / NoneStop Bit1/2Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station * The number of scans / link scans needed in this process varies depending on the specific requestCommunication Protocol CommunicationBoth send and receive requests are executed based on a dedicated commandNonprocedural Protocol CommunicationData is sent every time a send request is made while data can be received at all timesBidirectional Protocol CommunicationData is sent every time a send request is made while data can be received at all timesError DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameterChecksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol In the case of a non-procedural protocol, a checksum code is selected by a user-registered frameTransmission ControlRS-232DTR/DSR ControlAvailableRS/CS ControlAvailableCD Signal ControlAvailableDC1/DC3 (Xon/Xoff) ControlAvailableDC2/DC4 ControlAvailableRS-422/485DTR/DSR ControlNot availableRS/CS ControlNot availableCD Signal ControlNot availableDC1/DC3 (Xon/Xoff) ControlAvailableDC2/DC4 ControlAvailableCircuit Configuration (Target Equipment Side: CPU Unit Side)RS-232MELSEC Communication Protocol1:1Communication Protocol1:1Non-Procedural Protocol1:1Bidirectional Protocol1:1RS-422/485MELSEC Communication Protocol1:1, 1:n, m:n (the total of n and m+n cannot be greater than 32)Communication Protocol1:1, n:1 (n cannot be greater than 32)Non-Procedural Protocol1:1, 1:n, n:1 (n cannot be greater than 32)Bidirectional Protocol1:1Transmitting DistanceRS-232Maximum 15 mRS-422/485Maximum 1,200 m (total extension distance)Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)5 V DC Internal Current Consumption0.31 AExternal DimensionsHeight (H)98 mmWidth (W)27.4 mmDepth (D)90 mmWeight0.20 kg

QJ71C24N-R2 Specifications

InterfaceCH. 1RS-232 compliant (D-Sub 9P)CH. 2RS-232 compliant (D-Sub 9P)Communication MethodCircuitFull-duplex Communication / Half-duplex CommunicationMELSEC Communication Protocol CommunicationHalf-duplex communicationCommunication Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationNonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationBidirectional Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationSynchronization MethodAsynchronous methodTransmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps · 230,400 bps is available only on CH1 side (not available on CH2 side) · The total transmission speed of the two interfaces must be within 230,400 bps · When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bpsData FormatStart Bit1Data Bit7/8Parity Bit1 (Vertical parity) / NoneStop Bit1/2Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station * The number of scans / link scans needed in this process varies depending on the specific requestCommunication Protocol CommunicationBoth send and receive requests are executed based on a dedicated commandNonprocedural Protocol CommunicationData is sent every time a send request is made while data can be received at all timesBidirectional Protocol CommunicationData is sent every time a send request is made while data can be received at all timesError DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameterChecksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol In the case of a non-procedural protocol, a checksum code is selected by a user-registered frameTransmission ControlRS-232DTR/DSR ControlAvailableRS/CS ControlAvailableCD Signal ControlAvailableDC1/DC3 (Xon/Xoff) ControlAvailableDC2/DC4 ControlAvailableCircuit Configuration (Target Equipment Side: CPU Unit Side)RS-232MELSEC Communication Protocol1:1Communication Protocol1:1Non-Procedural Protocol1:1Bidirectional Protocol1:1Transmitting DistanceRS-232Maximum 15 mNumber of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)5 V DC Internal Current Consumption0.26 AExternal DimensionsHeight (H)98 mmWidth (W)27.4 mmDepth (D)90 mmWeight0.20 kg

QJ71C24N-R4 Specifications

InterfaceCH. 1RS-422/485 compliant (2-piece thrust-type terminal block)CH. 2RS-422/485 compliant (2-piece thrust-type terminal block)Communication MethodCircuitFull-duplex Communication / Half-duplex CommunicationMELSEC Communication Protocol CommunicationHalf-duplex communicationCommunication Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationNonprocedural Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationBidirectional Protocol CommunicationFull-duplex Communication / Half-duplex CommunicationSynchronization MethodAsynchronous methodTransmission Speed50, 300, 600, 1,200, 2,400, 4,800, 9,600, 14,400, 19,200, 28,800, 38,400, 57,600, 115,200, 230,400 bps · 230,400 bps is available only on CH1 side (not available on CH2 side) · The total transmission speed of the two interfaces must be within 230,400 bps · When the send/receive data monitoring function is used, the total transmission speed of the two interfaces must be within 115,200 bpsData FormatStart Bit1Data Bit7/8Parity Bit1 (Vertical parity) / NoneStop Bit1/2Access CycleMELSEC Communication Protocol CommunicationOne request is processed as part of the END processing of the sequencer CPU of the installed station * The number of scans / link scans needed in this process varies depending on the specific requestCommunication Protocol CommunicationBoth send and receive requests are executed based on a dedicated commandNonprocedural Protocol CommunicationData is sent every time a send request is made while data can be received at all timesBidirectional Protocol CommunicationData is sent every time a send request is made while data can be received at all timesError DetectionParity CheckApplicable to all protocols. If applicable, select odd or even number using a parameterChecksum CodeWhether to use a checksum code for MC protocol or that for bidirectional protocol is selected by a parameter In the case of a communication protocol, whether or not a checksum code is available is determined by the selected protocol In the case of a non-procedural protocol, a checksum code is selected by a user-registered frameTransmission ControlRS-422/485DTR/DSR ControlNot availableRS/CS ControlNot availableCD Signal ControlNot availableDC1/DC3 (Xon/Xoff) ControlAvailableDC2/DC4 ControlAvailableCircuit Configuration (Target Equipment Side: CPU Unit Side)RS-422/485MELSEC Communication Protocol1:1, 1:n, m:n (the total of n and m+n cannot be greater than 32)Communication Protocol1:1, n:1 (n cannot be greater than 32)Non-Procedural Protocol1:1, 1:n, n:1 (n cannot be greater than 32)Bidirectional Protocol1:1Transmitting DistanceRS-422/485Maximum 1,200 m (total extension distance)Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)5 V DC Internal Current Consumption0.39 AExternal DimensionsHeight (H)98 mmWidth (W)27.4 mmDepth (D)90 mmWeight0.20 kg