How many electrodes are needed to produce a 12-lead ecg?

How many electrodes and where? A "poldermodel" for electrocardiography

Jan A Kors et al. J Electrocardiol. 2002.

Abstract

It is known that body surface potential maps (BSPMs) contain diagnostic information not easily retrieved from the standard 12-lead electrocardiogram (ECG). Alternate lead sets that can reconstruct the BSPM have been proposed, but they are impractical because they require more than the 10 electrodes of the standard ECG and use nonstandard positions. We propose a practical approach to increasing the diagnostic information content of the standard ECG by repositioning selected chest electrodes. Thus, in the best tradition of the Dutch "poldermodel," we have sought to strike a compromise between the demands of different parties, one that, while suboptimal for each, will be seen by all as the best attainable result. We used a set of 746 120-lead BSPMs from healthy individuals and patients with various abnormalities. Data were split in a learning and a test set. Using the learning set, a general transformation to reconstruct all BSPM leads from the standard 12-lead ECG was derived by linear regression. Similarly, BSPMs were reconstructed when 2 of electrodes V(3)-V(6) were moved to other positions on the anterior part of the chest. Reconstruction performance was assessed on the test set by correlation and similarity coefficients. Thanks to the redundancy of information in the precordial leads, 2 missing precordial leads can be reconstructed from the others, using general coefficients, to a high degree of accuracy, particularly when the missing leads were not adjacent. We chose to reposition V(4) and V(6) to different sites on the anterior thorax. From the many electrode sites that we explored, those at 2 intercostal spaces below and above V(2) yielded better BSPM reconstruction than was attainable from the standard electrode positions, in most parts of the anterior thorax, including regions that are known to contain important diagnostic information less well brought forward by the standard ECG. Slight variations in the new electrode positions did not appreciably change the results. The standard 12-lead ECG proved to produce better overall reconstructions than either the EASI configuration or vectorcardiographic lead systems. Repositioning electrodes V(4) and V(6) provides a simple, practical method by which to improve the sampling of diagnostic information from the body surface while maintaining the full diagnostic content of the standard 12-lead ECG. This approach also obviates the need to determine the precise location of V(4) electrode, which may be difficult in women.

Similar articles

  • Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram.

    Finlay DD, Nugent CD, Nelwan SP, Bond RR, Donnelly MP, Guldenring D. Finlay DD, et al. J Electrocardiol. 2010 Nov-Dec;43(6):606-11. doi: 10.1016/j.jelectrocard.2010.07.004. Epub 2010 Sep 15. J Electrocardiol. 2010. PMID: 20832814

  • How many leads are necessary for a reliable reconstruction of surface potentials during atrial fibrillation?

    Guillem Mde L, Bollmann A, Climent AM, Husser D, Millet-Roig J, Castells F. Guillem Mde L, et al. IEEE Trans Inf Technol Biomed. 2009 May;13(3):330-40. doi: 10.1109/TITB.2008.2011894. IEEE Trans Inf Technol Biomed. 2009. PMID: 19423429

  • Improved EASI coefficients: their derivation, values, and performance.

    Feild DQ, Feldman CL, Horácek BM. Feild DQ, et al. J Electrocardiol. 2002;35 Suppl:23-33. doi: 10.1054/jelc.2002.37151. J Electrocardiol. 2002. PMID: 12539096

  • How many ECG leads do we need?

    Trägårdh E, Engblom H, Pahlm O. Trägårdh E, et al. Cardiol Clin. 2006 Aug;24(3):317-30, vii. doi: 10.1016/j.ccl.2006.04.005. Cardiol Clin. 2006. PMID: 16939826 Review.

  • Potential solutions for providing standard electrocardiogram recordings from nonstandard recording sites.

    Pahlm O, Wagner GS. Pahlm O, et al. J Electrocardiol. 2008 May-Jun;41(3):207-10. doi: 10.1016/j.jelectrocard.2008.02.001. J Electrocardiol. 2008. PMID: 18433611 Review.

Cited by

  • Calculating Cornell voltage from nonstandard chest electrode recording site in the Reasons for Geographic And Racial Differences in Stroke study.

    Soliman EZ, Howard G, Prineas RJ, McClure LA, Howard VJ. Soliman EZ, et al. J Electrocardiol. 2010 May-Jun;43(3):209-14. doi: 10.1016/j.jelectrocard.2009.10.002. Epub 2009 Dec 9. J Electrocardiol. 2010. PMID: 20004413 Free PMC article.

  • Mining for diagnostic information in body surface potential maps: a comparison of feature selection techniques.

    Finlay DD, Nugent CD, McCullagh PJ, Black ND. Finlay DD, et al. Biomed Eng Online. 2005 Sep 2;4:51. doi: 10.1186/1475-925X-4-51. Biomed Eng Online. 2005. PMID: 16138921 Free PMC article.

MeSH terms

How many electrodes are needed for a 12 lead ECG signal?

The standard ECG – which is referred to as a 12-lead ECG since it includes 12 leads – is obtained using 10 electrodes. These 12 leads consists of two sets of ECG leads: limb leads and chest leads. The chest leads may also be referred to as precordial leads.

Why does a 12 lead ECG have 10 electrodes?

Therefore, the ten electrodes in the 12 Lead ECG give 12 perspectives of the heart's electrical activity at a given time, using various angles. This is all done via two electrical planes called the horizontal and vertical planes discussed in the next section.

How many electrodes are used in a 12 lead ECG quizlet?

1. How many electrodes are used in a 12 lead ECG? 10 electrodes. A 12 lead ECG uses 4 limb and 6 chest electrodes for a total of 10 electrodes.

How many electrodes are needed to obtain a single ECG reading?

Thus, I will explain how to obtain the different 12 leads first and then one can choose which of them to use for measuring the ECG during exercise.