If this happens when trying to run the AutoCAD integrated version of the OpenFlows product, try the following Show
If this happens when opening plain AutoCAD (not integrated with an OpenFlows product) after accidentally opening the "... for AutoCAD..." shortcut, try the following:
See AlsoError message in AutoCAD integrated version: "FATAL ERROR: Cannot write to undo file (probably disk full)" "Fatal Error: Unhandled access violation reading 0x0000 exception at 9a32a5c8h." when starting AutoCAD Civil 3D integration In terms of error messages, an "exception" is a known error type. An "unhandled exception" in AutoCAD when using Land F/X means that the AutoCAD or Land F/X code can't account for a particular exception that is occurring. There are myriad Unhandled exception errors, and your solution will depend on the exact text of the error and, in many cases, what you were trying to do in AutoCAD when you saw the error. Here are several specific Unhandled exception errors we've encountered, along with their causes and solutions: CauseIf you saw this Unhandled exception error when attempting to create a keyboard shortcut (alias) for an AutoCAD or Land F/X command. If so, you likely do not have full access to the folder containing the alias files. You should see the name of this file path at the bottom of the error dialog box, as pictured below. In our example, we do not have access to the path C:\program files\autodesk\autocad\2015\express\alias.pgc – the alias file. SolutionTo correct this issue, you'l need to change your permissions so you are able to access the alias file. You may need to contact your office's IT administrator to complete these steps. Open your Start menu and navigate to the file path shown in the error dialog box. In our case, we will navigate to the folder path C:\program files\autodesk\autocad\2015\express and then locate the file named alias.pgc. Right-click the alias file, then select Properties from the menu that opens. The Properties dialog box will open for the selected file. With the Security tab open, find and highlight your username in the Group or user names section. Check the Permissions for Users area to find out whether you have full permission for this file. In the above example, the user only has Read & Execute and Read permissions. Click Edit to open the Permissions dialog box for this file. Check the Full Control box in the Permissions for Users section, then click Apply. You should now see checks next to all permissions except Special Permissions in the Properties dialog box. Click OK to close this dialog box. You should now have full permissions for the alias file. You can now . AutoCAD crashed, and you saw an error message similar to the following one when using AutoCAD 2017 or Civil 3D 2017. Fatal Error: Unhandled Access Violation Reading 0x70d94980 Exception at fb8a7664hYou may also have seen a message similar to this one: FATAL ERROR: Unhandled e0434352h Exception at fd5ba06dh CauseWe've been seeing this issue from time to time with AutoCAD and AutoCAD Civil 3D 2017 installations. A quick fix from AutoCAD Service Pack 1 will take care of the problem. Solution1. You might see the error message pictured to the left as well. Click No to close the error message. 2. See Autodesk's AutoCAD 2017 Service Pack 1 page. 3. Scroll down on the Service Pack 1 page until you see the download options pictured to the left. Click the correct AutoCAD 2017 SP1 version for your computer (64-bit or 32-bit). This step will actually require you to download and install two separate files When you click the download link, your browser will either prompt you to download multiple files or open a secondary pop-up window, which may be easily overlooked or hiding behind the browser. (What you see will depend on your browser settings.) You may need to poke around a bit to find them. See the images below for examples. Using Google Chrome? You should see a message that the Autodesk site wants you to download multiple files. Click Allow. Using Mozilla Firefox? You'll have two download windows, which may or may not be hidden behind the browser window. Click Save File in each message. 4. The following two files will download to your computer:
Take note of the file names, and save the files in a location where you can find them easily. 5. Run each of the files you downloaded. Allow a few minutes for the Service Pack to install and repair your installation. 6. You'll see a message that the service pack was installed successfully. Click OK. You should now be able to use AutoCAD 2017 or AutoCAD Civil 3D 2017 without getting the error. You may have seen this error when either launching AutoCAD or F/X CAD or opening a drawing file. You may have also seen one or both of the following errors after clicking Accept in the original error message:
CauseA Windows 10 Region setting in Windows 10 is preventing AutoCAD or F/X CAD from working properly. Solution1. Open the Windows Start menu and type Region in the search box. Select the Region settings option at the top of the menu. 2. In the Region window, click Additional date, time, & regional settings. 3. In the Clock and Region window, click Region. 4. In the Region dialog box, select the Administrative tab. Click Change system locale ... . 5. In the Region Settings dialog box, uncheck the Beta: Use Unicode UTF-8 for worldwide language support option. |